The weakest part on the balcony or terrace is the incline of cement floor base, which of his building in technology has a porous structure. Near the function of incline, the cement floor base is used as an application for ceramics lining but also as a protection of eventual bitumen hydro isolation on the concrete board. In the case of local irruption of moisture into inclined cement floor base is this one because of his porous structure unimpeded spreading over the entire surface. The moisture is usually because of the falls accumulating on the front of the balcony but it can also come to interior spaces at the balconies surface.
With cyclic freezing and melting of moisture at the inclined cement floor base it can lead going across of the boarder tensions and with that to decomposition of cement floor base. At long-term it can also come to deviation of final lining and to injuries of carrying construction.
We can assure waterproof surface - of cement floor base on the balcony and terrace constructions by using waterproof coatings on cement basis
HIDROSTOP ELASTIK. Layer is reinforced with plaster with glass net. Into the connections of crossing on the walls we build in
KEMABAND sealing ribbon. On only that way prepared surfaces we can start with laying of final lining where for setting we can use one of the flexible cement adhesive as
KEMAKOL PLAST 190,
KEMAKOL RAPID 193 or
KEMAKOL FLEX 170. For grouting of surfaces we use
FULL grouting compound and the movable connections and dilatations we seal with permanently elastic sealing compound
KEMAFLEX MS.